What the Irrigation Water Calculator does
The Irrigation Water Calculator works out water to apply, litres and flow needed from field area (acres), water depth to apply (mm) and application efficiency (%). Land area, seed, fertiliser and yield estimates, including acre, kanal and marla conversions.
It runs in your browser and nothing you type is uploaded.
Before you start
You need 3 values and may add 1 optional one:
- Field area (acres): A number: greater than zero.
- Water depth to apply (mm): A number: greater than zero.
- Application efficiency (%): A number: greater than zero, at most 100.
- Hours available (optional): A number: greater than zero.
Step by step
- Open the Irrigation Water Calculator.
- Enter Field area (acres).
- Enter Water depth to apply (mm).
- Enter Application efficiency (%).
- Add hours available if you want it included, or leave it empty.
- Press Calculate. Every field that needs fixing is listed next to it.
- Read the main result first, then the other lines. Open Formula and assumptions to see how it was worked out.
- Use Copy to keep the result, and add the calculator to your favourites if you use it often.
A worked example
With these sample values (they are only an illustration; use your own):
| Field area (acres) | 10 |
|---|---|
| Water depth to apply (mm) | 10 |
| Application efficiency (%) | 60 |
| Hours available (optional) | 8 |
the calculator gives:
| Water to apply | 674.5 m³ |
|---|---|
| Litres | 674,476 |
| Flow needed | 23.42 L/s |
The example is the real output of this calculator.
Reading your result
The result lists: water to apply, litres and flow needed.
The formula it uses:
volume = area × depth ÷ efficiency
Common mistakes
- Use the same units for every value.
- Enter rates as a percentage per period shown in the label, for example 12 for 12%, not 0.12.
- Optional fields can stay empty. Required fields cannot.
- Treat the result as an estimate: real quotes, rules and rounding can differ.